- Because conventional single - terminal method of fault location ca n ' t eliminate the influence of fault resistance and the remote in - feed , its utility is limited
单端测距法由于存在难以消除过渡阻抗和对端系统阻抗的影响这一缺陷,使其应用受到限制。 - The principles of selecting fault line in existence can also be used in feeder automation . these principles may increase the reliability of fault location greatly
同时指出现有的选线原理同样可以用于本方案,这些原理的应用将大大增加单相接地故障定位的可靠性。 - Quick and accurate fault location is the premise to rapidly isolate the fault and redelivery power supply , and it is important to the normal working of power networks
快速、准确的故障定位是迅速隔离故障和恢复供电的前提,对于维护配电网的安全运行具有重要意义。 - An automatic fault location method is proposed based on ftu after the circuit analysis of single line - to - ground fault in distribution networks
通过对配电网发生单相接地故障后馈线的电压、电流变化规律的分析,论文提出了基于馈线现场监控终端ftu的故障点智能定位方法。 - After a comprehensive analysis of existing methods , the author made a thorough study with the on - line monitoring method and a fault location algorithm
论文对国内外关于该课题的现有的各种研究情况做了全面深入的分析,在此基础上从接地故障测距算法和在线监测两方面进行了研究。 - It's difficult to find fault location in a sentence. 用fault location造句挺难的
- With the requirement of improving the reliability of power supply and the fast development of the distributed power system automation , the study of fault location becomes more and more important
提高供电可靠性的要求和配电网自动化水平的迅猛发展使得对故障定位的研究日益紧迫。 - The merit of travelling waves location is its high precision , but it has dead line if the fault location is close to the line terminal or the fault occurs at the time close to zero point of current
行波法测距的优点是精度高,但对近区故障或电流过零附近时刻发生的故障存在测距死区。 - The association rules got from this database can be used in alarm associating , alarm filtrating , fault location and forecasting and effectively promote the intelligent network management
挖掘出的关联规则可以应用于告警过滤、告警关联、故障定位和故障预测等,可有效提高网络的智能化管理。 - In the method zero sequence voltage is discussed and new principle for automatic fault location and isolation based on the zero sequence voltage is presented in this paper
该方法以馈线电压变化量为故障点定位的主要判据进行故障点自动监测与定位,并迅速隔离故障区段,恢复正常区段的供电。 - The single - phase grounding fault frequently occurs in neutral ungrounded system , the fault line and fault location must be found to avoid a phase - to - phase short as soon as possible
单相接地故障在小电流接地系统中出现的比较频繁,此时必须尽快找到故障线路以及大致的故障点,以避免两相对地短路。 - Based on principles of radar , there brings up a general scheme of fault diagnosis system and detailed description to fault module division , fault location and setup of fault tree
在介绍雷达原理的基础上,提出了故障诊断系统的总体方案,对故障块的划分,检测点的确定,故障树的建立等进行了详细说明。 - Secondly the present fault location on hv transmission network has been commented on . tree fault location methods based on the power frequency fault data of two - terminal are proposed
本文其次对现有高压输电线路故障定位方法进行了综合评述,在此基础上提出了三种基于双端数据的工频故障测距算法。 - Tmn implements the management and control functions by using a workstation , include fault analysis , fault location and the performance analysis of the whole network
电信网络管理系统是通过一个网管工作站实现对互连的电信网络实施各种管理和控制,包括全网故障分析和故障定位、全网性能综合分析等功能。 - But owing to the short development history of faults location techniques and the limits of related techniques , fault location devices with high precision are not widely used in practice
但由于故障测距技术本身发展的历史并不长和相关技术条件的限制,具有较高精度的故障测距装置在实际中的应用并不多。 - Considering effect of robustness of algorithms , two new algorithms for two - terminal fault location with a form of fraction are brought forward , which avoid the data synchronization between the two terminals
在对其鲁棒性分析的启示下,提出了2种不需要双端(或多端)数据同步的分式型工频双端测距新算法。